  "passed": true,
  "original": {
    "study": "Panel schedule",
    "panel_id": "TEST-PANEL",
    "circuits": [
      {
        "id": "C1",
        "slots": [
          1
        ],
        "phases": [
          "A"
        ],
        "connected_va": 800,
        "demand_va": 800
      },
      {
        "id": "C2",
        "slots": [
          2
        ],
        "phases": [
          "B"
        ],
        "connected_va": 600,
        "demand_va": 600
      },
      {
        "id": "C3",
        "slots": [
          3
        ],
        "phases": [
          "C"
        ],
        "connected_va": 500,
        "demand_va": 500
      }
    ],
    "phase_connected_va": {
      "A": 800.0,
      "B": 600.0,
      "C": 500.0
    },
    "phase_demand_va": {
      "A": 800.0,
      "B": 600.0,
      "C": 500.0
    },
    "total_connected_va": 1900.0,
    "total_demand_va": 1900.0,
    "scope": "Multipole loads are split equally across declared phases."
  },
  "phase_reassignment": {
    "study": "Panel schedule",
    "panel_id": "TEST-PANEL",
    "circuits": [
      {
        "id": "C1",
        "slots": [
          1
        ],
        "phases": [
          "A"
        ],
        "connected_va": 800,
        "demand_va": 800
      },
      {
        "id": "C2",
        "slots": [
          2
        ],
        "phases": [
          "A"
        ],
        "connected_va": 600,
        "demand_va": 600
      },
      {
        "id": "C3",
        "slots": [
          3
        ],
        "phases": [
          "C"
        ],
        "connected_va": 500,
        "demand_va": 500
      }
    ],
    "phase_connected_va": {
      "A": 1400.0,
      "B": 0.0,
      "C": 500.0
    },
    "phase_demand_va": {
      "A": 1400.0,
      "B": 0.0,
      "C": 500.0
    },
    "total_connected_va": 1900.0,
    "total_demand_va": 1900.0,
    "scope": "Multipole loads are split equally across declared phases."
  },
  "multipole": {
    "study": "Panel schedule",
    "panel_id": "TEST-PANEL",
    "circuits": [
      {
        "id": "C1",
        "slots": [
          1
        ],
        "phases": [
          "A"
        ],
        "connected_va": 800,
        "demand_va": 800
      },
      {
        "id": "C2",
        "slots": [
          2
        ],
        "phases": [
          "A"
        ],
        "connected_va": 600,
        "demand_va": 600
      },
      {
        "id": "C3",
        "slots": [
          3
        ],
        "phases": [
          "C"
        ],
        "connected_va": 500,
        "demand_va": 500
      },
      {
        "id": "C4",
        "slots": [
          4,
          5
        ],
        "phases": [
          "A",
          "B"
        ],
        "connected_va": 400,
        "demand_va": 200.0
      }
    ],
    "phase_connected_va": {
      "A": 1600.0,
      "B": 200.0,
      "C": 500.0
    },
    "phase_demand_va": {
      "A": 1500.0,
      "B": 100.0,
      "C": 500.0
    },
    "total_connected_va": 2300.0,
    "total_demand_va": 2100.0,
    "scope": "Multipole loads are split equally across declared phases."
  },
  "catalog": {
    "study": "Pinned equipment catalog",
    "equipment": [
      {
        "equipment_id": "coil",
        "catalog_id": "trainer-coil",
        "revision": 1,
        "source": "Synthetic revision fixture",
        "properties": {
          "rated_a": 10
        }
      }
    ]
  },
  "missing_revision_and_overlapping_slots_rejected": true,
  "cad_import_preserved_results": true,
  "csv_export_verified": true
}