ElectraNalis

Control panel

Technicians reviewing components on a demonstration control panel

Lay out the circuits and review the connected load before detailed design.

Sample distribution one-line

Use this example to see how the equipment fits together. Replace the example ratings with your equipment data for your project.

  1. Service source480 V, three-phase
  2. Switchboard SWBD-1480 V main distribution
  3. Transformer T1480 V to 208Y/120 V
  4. Panelboard LP-1208Y/120 V branch distribution
  5. Long feeder F1300 ft one-way example
  6. Motor M1208 V, three-phase

What to study

Download the switchboard-to-motor project · Open the load-flow and feeder-outage results

Review the 300 ft feeder

Run the saved file with python project.py voltage-drop ElectraGrid-feeder.json.

Open running and starting voltage-drop results · Compare ampacity and drop checks · Download the candidate comparison CSV

The feeder reports use synthetic cable inputs and limits to demonstrate the study workflow.

Run the motor-start example

Synthetic motor start against a 3.90 s test limit
ModelTime to targetResult
Fixed starting voltage4.06 sExceeds test limit
Speed-dependent impedance3.76 sWithin test limit

Open the deadline comparison inputs and results

Download the motor-start project · Open motor-start results

Place the project in the extracted release folder and run python project.py motor-start panel-motor-start-project.json.

This example calculates the starting terminal voltage from the feeder model, then holds that voltage constant during acceleration.

For voltage and current at multiple speeds, download the speed-dependent project or open the speed profile CSV. Run python project.py motor-start panel-motor-speed-project.json --output speed.csv to reproduce it.

The study file uses assumed per-unit impedances. The illustrated 300 ft route does not determine the study impedance.

Open study examples · Create the terminal drawing

Panel layout and connected load

Download a combined example and open it below to see the panel circuits and attached drawing and feeder inputs. View the example results · Open the generated terminal sheet.

Generate all three outputs from the combined example

Save the example in the extracted ElectraNalis release folder, then run these commands for the circuit schedule, terminal sheet, and feeder study.

python project.py panel-schedule combined-panel-example.json
python project.py drawing combined-panel-example.json --output terminal.html
python project.py voltage-drop combined-panel-example.json

Add phase-to-neutral loads using their nameplate VA. Three-phase motor loads are shown in the one-line and require a separate motor and feeder study.

Circuit layout

    To generate a panel schedule, save the project and run python project.py panel-schedule ElectraGrid-panel.json from the extracted ElectraNalis release.

    
    

    This study totals the assigned VA by phase. Use the Drawings tab for terminal wiring. Fault duty, protective coordination, and engineering approval are separate reviews.